Dell Intel SSD DC P4510 Series 1TB NVMe U.2 Enterprise SSD
Dell Intel SSD DC P4510 Series 1TB NVMe U.2 Enterprise SSD
Price on Request
PN:SSDPE2KX010T8D
Quick Specifications
Memory1.0TB / 1000GB
PCIePCIe 3.1 x4, NVMe 1.2
Form Factor2.5-inch 15mm U.2
Dell Part Number0VY9M / 00VY9M
Product CollectionIntel SSD DC P4510 Series (Dell OEM Certified)
Product TypeEnterprise NVMe Solid-State Drive
NAND FlashIntel 64-Layer 3D TLC NAND
Sequential ReadUp to 2,850 MB/s
1
Order on WhatsApp
Share to:

Technical Specifications

Hardware Features

Brand
Dell EMC / Intel
Model
Dell Intel SSD DC P4510 Series 1.0TB
Model Number
SSDPE2KX010T8D
Dell Part Number
0VY9M / 00VY9M
Capacity
1.0TB / 1000GB
Form Factor
2.5-inch 15mm U.2
Interface
PCIe 3.1 x4, NVMe 1.2
NAND Flash Memory
Intel 64-Layer 3D TLC NAND
Interface Bandwidth
Up to 4 GB/s (PCIe 3.0 x4)
Dimensions
100.45 × 69.85 × 15.0 mm
Weight
Approx. 140 g

Network Performance

Sequential Read Speed
Up to 2,850 MB/s
Sequential Write Speed
Up to 1,100 MB/s
Read Latency (Typical)
10 µs
Write Latency (Typical)
30 µs

System and Support

Power Loss Protection
Enhanced Power Loss Protection (Capacitor-Backed)
MTBF
2,000,000 Hours
Operating Temperature
0–70°C
Service and Support
INOVEXA TECHNOLOGIES Bangladesh
Mean Time Between Failures (MTBF)
2,000,000 Hours
Power Loss Protection (PLP)
Enhanced Power Loss Protection (Capacitor-Backed)
Active Power Consumption
Up to 12W Active
Idle Power Consumption
5.0W
Non-Operating Temperature
-55°C to 95°C
Service & Support
INOVEXA TECHNOLOGIES Bangladesh

General Specifications

Product Collection
Intel SSD DC P4510 Series (Dell OEM Certified)
Product Type
Enterprise NVMe Solid-State Drive
NAND Flash
Intel 64-Layer 3D TLC NAND
Sequential Read
Up to 2,850 MB/s
Sequential Write
Up to 1,100 MB/s
Random Read (100% Span)
Up to 465,000 IOPS (4KB)
Random Write (100% Span)
Up to 70,000 IOPS (4KB)
Endurance (PBW / DWPD)
1.92 PBW (1,920 TBW) / 1.0 DWPD for 5 Years
Hardware Encryption
AES 256-bit Encryption
UBER
1 Sector per 10¹⁷ Bits Read
Active Power
12W Active
Idle Power
5.0W
Target Servers
Dell PowerEdge R630, R730, R640, R740, R740xd, R840, R940
Random Read (4KB, 100% Span)
Up to 465,000 IOPS
Random Write (4KB, 100% Span)
Up to 70,000 IOPS
Endurance Rating (TBW / DWPD)
1.92 PBW (1,920 TBW) / 1.0 DWPD for 5 Years
Uncorrectable Bit Error Rate (UBER)
1 sector per 10¹⁷ bits read
End-to-End Data Protection
Yes, full internal data path CRC
Enterprise Duty Cycle
24×7 Continuous Operation
Supported Dell Servers
Dell PowerEdge R630, R730, R640, R740, R740xd, R840, R940
Technical Guidance
Dell NVMe PCIe Extender & Backplane cable verification available

Product Description

Dell Intel SSD DC P4510 Series 1TB NVMe U.2 Enterprise SSD

Looking for validated, high-throughput enterprise NVMe storage for your Dell PowerEdge servers? The Dell Intel SSD DC P4510 Series 1.0TB NVMe U.2 Enterprise SSD (Dell P/N: 0VY9M / Model: SSDPE2KX010T8D) is a high-performance PCIe 3.1 x4 solid-state drive certified and tuned for Dell EMC PowerEdge rack and blade servers. Powered by Intel 64-layer 3D TLC NAND technology in a 2.5-inch 15mm U.2 form factor, it delivers sequential reads up to 2,850 MB/s, sequential writes up to 1,100 MB/s, and up to 465,000 random-read IOPS. Designed for high-density virtualization, database indexing, software-defined storage (vSAN), and big data analytics, it incorporates full capacitor-backed Power Loss Protection, end-to-end CRC data validation, Dell certified firmware, and an enterprise endurance rating of 1.0 DWPD (1.92 PBW) for 5 years in Bangladesh.

Enterprise Performance and Architectural Overview

The Dell Intel DC P4510 1TB NVMe SSD bridges the gap between massive solid-state capacity and high-bandwidth PCIe NVMe performance. Bypassing legacy SATA and SAS controller bottlenecks, it connects directly to the server PCIe bus via a 2.5-inch U.2 backplane. Engineered with Dell certified firmware for seamless iDRAC lifecycle management, automated drive health monitoring, and predictable low-latency QoS, the P4510 delivers continuous 24/7 reliability for mission-critical Dell PowerEdge R630, R730, R640, R740, and R740xd server deployments across Bangladesh.

Advanced Technical Standards and Multi-Gigabit Support

  • PCIe 3.1 x4 NVMe Architecture: Direct high-bandwidth PCIe interface delivers up to 2,850 MB/s sequential read and 465,000 random-read IOPS.
  • Dell OEM Certified Firmware (PN: 0VY9M): Engineered for seamless integration with Dell PowerEdge iDRAC health reporting and Dell RAID/HBA controllers.
  • Intel 64-Layer 3D TLC NAND: Provides high storage density, thermal efficiency, and consistent solid-state performance.
  • Hardware Power Loss Protection (PLP): Capacitor-backed PLP ensures all cached data and command queues are safely committed to flash if server power fails.
  • Endurance Rating of 1.0 DWPD (1.92 PBW): Rated for 1.92 PBW over 5 years, supporting continuous cloud virtualization and database indexing.
  • End-to-End Data Path Protection & AES-256: Protects against silent data corruption and secures business data with hardware-level AES 256-bit encryption.

Reliability and Long-Term Performance in Bangladesh

Electronic components and network equipment in our region need to be durable to handle varying environmental conditions. Every enterprise unit supplied by INOVEXA Technologies is tested under intensive operational benchmarks to guarantee 24/7 continuous operation, optimized thermal airflow, and long lifespan.

Secure Your High-Performance Hardware at INOVEXA

Do not let hardware bottlenecks hold back your business network or workstation. We maintain ready stock of genuine enterprise hardware backed by fast nationwide delivery across Bangladesh, replacement warranty, and dedicated engineering support.

Benefits & Enterprise Applications

Enterprise Applications & Deployments

Dell PowerEdge High-Speed Storage Tiers

Direct NVMe connectivity for PowerEdge 13G and 14G server U.2 backplanes.

VMware vSAN & Hyperconverged Infrastructure (HCI)

Provides high IOPS and ultra-low latency for vSAN caching and capacity tiers.

Transactional & Analytics Databases

Accelerates Oracle, PostgreSQL, MS SQL, and MongoDB query execution and indexing.

AI Training & Big Data Ingestion

Delivers 2,850 MB/s sustained sequential read throughput for large dataset processing.

High-Density Virtual Machine Clusters

Eliminates storage I/O bottlenecks across multi-tenant cloud virtualization hosts.

Operational & ROI Benefits

Up to 5x Faster than SATA SSDs

Delivers up to 2,850 MB/s read bandwidth and 465K IOPS over direct PCIe 3.0 x4 NVMe lanes.

Dell Certified Hardware & Firmware

Ensures full iDRAC compatibility, temperature monitoring, and hassle-free firmware maintenance.

Hardware Power Loss Protection

Protects critical database records and cached writes during unexpected power outages.

Low Latency (~10µs Read)

Massively reduces wait times for transaction-heavy enterprise applications.

System & Hardware Compatibility

Certified Operating Systems & Hypervisors

  • VMware ESXi 6.7/7.0/8.0
  • Proxmox VE 7/8
  • Windows Server 2016/2019/2022
  • RHEL 7/8/9
  • Ubuntu Server 20.04/22.04/24.04
  • Debian
  • FreeBSD

Hardware Chassis & Interconnect Platform

  • Dell PowerEdge R630/R730/R640/R740/R740xd/R840/R940
  • Dell PowerEdge C6420
  • Supermicro NVMe Chassis
  • HPE ProLiant NVMe Servers
  • PCIe U.2 Host Adapter Cards

Supported Network & Storage Protocols

PCIe 3.1 x4NVMe 1.2Enhanced Power Loss Protection (PLP)AES 256-bit EncryptionS.M.A.R.T. NVMe Log Pages

Deployment & Buying Guide

Recommended Deployment Pairing

Requires a server or chassis with a 2.5-inch U.2 NVMe backplane and PCIe NVMe cabling / PCIe extender card (e.g. Dell PowerEdge NVMe PCIe Extender).

Ideal Infrastructure Use Cases (Best For)

Dell PowerEdge R630, R730, R640, R740, R740xd, R840, R940 NVMe Bays
VMware vSAN, Proxmox VE, and Microsoft Azure Stack HCI Nodes
High-Speed Database Caching and Transaction Logging
High-Performance Computing (HPC) & Analytics Clusters

Key Deployment & Integration Considerations

  • Verify that your Dell PowerEdge server is equipped with an NVMe backplane and PCIe cable connections to the motherboard or PCIe extender card.
  • Standard 2.5-inch 15mm U.2 drive requires a standard Dell 2.5" drive caddy with appropriate labeling.
  • Ensure the server BIOS is set to UEFI mode for NVMe boot capability.

FAQs

Reviews & Ratings

4.8out of 5.0
(0 reviews)

There have been no reviews for this product yet.

Why Choose INOVEXA?

Data Center Grade Reliability

Tested under high-temperature and high-throughput workloads to guarantee 24/7 uptime.

Bulk Order & System Customization

Tailored hardware provisioning, memory scaling, and port expansion for bulk deployments.

Dedicated Account Management

Single point of contact for technical quotes, warranty claims, and infrastructure upgrades.

End-to-End Local Support in BD

Dedicated technical hotline and on-site support options for business infrastructure.

Related Products